Setup Ethernet Parameter, Data Rate – Rate type
There are two modes: Nx64K model and T1 mode. When the remote side has T1 interface and unframed mode connect to
this side as Ethernet interface, we must set Ethernet rate mode as T1 mode.
Setup Ethernet Parameter, Data Rate
For 2-wires with Annex A and B, the rate can be adjusted in increments of 64kbps from 64kbps to 2304kbps (N=1~36).
For 2-wires with Annex F and G, the rate can be adjusted in increments of 64kbps from 192kbps to 5696kbps (N=3~89).
For 4-wires with Annex A and B, the rate can be adjusted in increments of 64kbps from 128kbps to 4608kbps (N=2~72, even
number only).
For 4-wires with Annex F and G, the rate can be adjusted in increments of 64kbps from 384kbps to 11392kbps (N=6~178, even
number only).